TeSys D – Contactor – 3P AC-3 – <=440 V 9 A – bobina 220 V CA
gama TeSys
TeSys Deca
nombre del producto TeSys D
TeSys DF
tipo de producto o componente Conector
nombre corto del dispositivo LC1D
aplicación del contactor Control del motor
Carga resistiva
categoría de empleo AC-4
AC-3
AC-1
número de polos 3P
power pole contact composition 3 NA
[Ue] tensión asignada de empleo Power circuit: <= 690 V AC 25…400 HzPower circuit: <= 300 V DC
[Ie] corriente asignada de empleo 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
potencia del motor en kW 2.2 kW at 220…230 V AC 50/60 Hz (AC-3)
4 kW at 380…400 V AC 50/60 Hz (AC-3)
4 kW at 415…440 V AC 50/60 Hz (AC-3)
5.5 kW at 500 V AC 50/60 Hz (AC-3)
5.5 kW at 660…690 V AC 50/60 Hz (AC-3)
2.2 kW at 400 V AC 50/60 Hz (AC-4)
motor power HP (UL / CSA) 1 hp 230/240 V CA 50/60 Hz 1 fase
2 hp 200/208 V CA 50/60 Hz 3 fases
2 hp 230/240 V CA 50/60 Hz 3 fases
5 hp 460/480 V CA 50/60 Hz 3 fases
7.5 hp 575/600 V CA 50/60 Hz 3 fases
0.33 hp 115 V CA 50/60 Hz 1 fase
tipo de circuito de control AC at 50/60 Hz
[Uc] tensión del circuito de control 220 V AC 50/60 Hzcomposición de los contactos auxiliares 1 NA + 1 NC
[Uimp] Tensión asignada de resistencia a los choques 6 kV conforming to IEC 60947categoría de sobretensión III
[Ith] corriente térmica convencional 25 A (at 60 °C) for power circuit10 A (at 60 °C) for signalling circuit
Irms poder de conexión nominal 250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
poder asignado de corte 250 A at 440 V for power circuit conforming to IEC 60947
[Icw] Corriente temporal admisible 105 A 40 °C – 10 s for power circuit210 A 40 °C – 1 s for power circuit
30 A 40 °C – 10 min for power circuit
61 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
fusible asociado 10 A gG for signalling circuit conforming to IEC 60947-5-1
25 A gG at <= 690 V coordination type 1 for power circuit
20 A gG at <= 690 V coordination type 2 for power circuit
ABB A185-30 - Contactor
A110-30-11 ABB Contactor
ADAPTADOR DE ROSCA DE E40 A E27
LIMIT SWITCH LOVATO KB F1 S11
Bombillo Ahorrador Espiral 75 Watt Ah39 - Lumistar
Telemecanique LC1D12 - Contactor
Schneider Electric GV2ME06 - Guardamotor
ABBF OFAF000H63 FUSIBLE 500 V
Exceline Breaker 1x20 Empotrar GQL
SP715ALL VALVULA HAYWARD VARI-FLO 125GPM Y 50PSI
FERRAZ SHAWMUT A50P300-4 FUSIBLE
SCHNEIDER ELECTRIC GV2-ME16C - GUARDAMOTOR
Telemecanique LC1D09 Contactor
Control de Temperatura ON/OFF XH-W3001 Termostato/Incubadora
Schneider Electric LC1D09M7 - Contactor
Norgren R07-100-RNKA Regulador miniatura
Schneider Electric GV2ME32 Guardamotor
SCHNEIDER ELECTRIC RELE 12-18A LRD21
PUNTO DE CONTACTO DEL INDICADOR DE PRUEBA DE CUADRANTE 1 MM - # 103013
CSQ LC1D32 - Contactor
A9-30-10 - ABB Contactor
CINTA TEFLON PTFE SHURTAPE
TEMFLEX 1500 3M CINTA AISLANTE VINILO
LRD16C Schneider Electric Relé de Sobrecarga Térmica para Motor
UT333 UNI-T TERMOHIGROMETRO DIGITAL
BULLETIN 889D ALLEN BRADLEY
Jackson Palmer Juego de 218 puntas de destornillador, acero al carbono de alta calidad, incluye puntas de seguridad.
SCHNEIDER ELECTRIC LADN31C BLOQUE DE CONTACTO
3RH1911-1FA22 SIEMENS BLOQUE DE CONTACTO 2NA+2NC
Interruptor de palanca Panel multifunción para coche barco marino RV camión Camper vehículos 12V/24V 













Valoraciones
No hay valoraciones aún.