| range | TeSys TeSys Deca |
| product name | TeSys D TeSys Deca |
| product or component type | Contactor |
| device short name | LC1D |
| contactor application | Resistive load Motor control |
| utilisation category | AC-1 AC-4 AC-3 |
| poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
| [Ie] rated operational current | 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
| motor power kW | 3 kW at 220…230 V AC 50/60 Hz (AC-3) 5.5 kW at 380…400 V AC 50/60 Hz (AC-3) 5.5 kW at 415…440 V AC 50/60 Hz (AC-3) 7.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 660…690 V AC 50/60 Hz (AC-3) 3.7 kW at 400 V AC 50/60 Hz (AC-4) |
| motor power HP (UL / CSA) | 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors 3 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| control circuit type | DC standard |
Schneider Electric LC1D12F7 – Contactor
| range | TeSys TeSys Deca |
| product name | TeSys D TeSys Deca |
| product or component type | Contactor |
| device short name | LC1D |
| contactor application | Resistive load Motor control |
| utilisation category | AC-1 AC-4 AC-3 |
| poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
| [Ie] rated operational current | 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
| motor power kW | 3 kW at 220…230 V AC 50/60 Hz (AC-3) 5.5 kW at 380…400 V AC 50/60 Hz (AC-3) 5.5 kW at 415…440 V AC 50/60 Hz (AC-3) 7.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 660…690 V AC 50/60 Hz (AC-3) 3.7 kW at 400 V AC 50/60 Hz (AC-4) |
| motor power HP (UL / CSA) | 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors 3 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| control circuit type | DC standard |
ABB A40-30-10 - Contactor
BULLETIN 889D ALLEN BRADLEY
Bussmann / Eaton 125NH1- Fusible
3M CINTA DE URETANO 4026W DOBLE REVESTIMIENTO
Telemecanique LC1D12 - Contactor
Schneider Electric LC1D09M7 - Contactor
Extech DT100M Medidor de distancia
Siemens 6ED1 055-1MA00-0BA2 módulo de entrada analógica
General Electric Breaker Trifasico 3x200 Amp -
CINTA DE EMPAQUE MARRON 48MMX35M
ATA450DU ABB 1SAZ511201R1003 RELE DE SOBRECARGA TERMICA 220….310A
Exceline Flotante Eléctrico
CROUZET GMS-OAC 84130105 Relé de estado sólido
ALLEN BRADLEY 1492-SP1B030 BREAKER
MAXIFLEX ULTIMATE GUANTES DE SEGURIDAD 34-874 TALLA XXL
General Electric Ted134100wlb Breaker Industrial
PROFIBUS BK3150 Acoplador de bus compacto
Telemecanique LC1D09 Contactor
LEVITON T5633-2BW TOMA CORRIENTE 5.1A (25W) CARGADOR USB 15A-125V
CINTA DE EMPAQUE TRANSPARENTE 48X35M
TEMFLEX 1500 3M CINTA AISLANTE VINILO
A26-30-01 ABB Contactor 












Valoraciones
No hay valoraciones aún.