| range | TeSys TeSys Deca |
|---|---|
| product name | TeSys D TeSys Deca |
| product or component type | Contactor |
| device short name | LC1D |
| contactor application | Resistive load Motor control |
| utilisation category | AC-3 AC-4 AC-1 AC-3e |
| poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
| [Ie] rated operational current | 32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 32 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| motor power kW | 7.5 kW at 220…230 V AC 50/60 Hz (AC-3) 15 kW at 380…400 V AC 50/60 Hz (AC-3) 15 kW at 415…440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660…690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC-4) 7.5 kW at 220…230 V AC 50/60 Hz (AC-3e) 15 kW at 380…400 V AC 50/60 Hz (AC-3e) 15 kW at 415…440 V AC 50/60 Hz (AC-3e) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 660…690 V AC 50/60 Hz (AC-3e) |
| motor power HP (UL / CSA) | 2 hp at 115 V AC 50/60 Hz for 1 phase motors 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 20 hp at 460/480 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 24 V AC 50/60 Hz |
| auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| overvoltage category | III |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit 50 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 550 A at 440 V for power circuit conforming to IEC 60947 |
| rated breaking capacity | 550 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 260 A 40 °C – 10 s for power circuit 430 A 40 °C – 1 s for power circuit 60 A 40 °C – 10 min for power circuit 138 A 40 °C – 1 min for power circuit 100 A – 1 s for signalling circuit 120 A – 500 ms for signalling circuit 140 A – 100 ms for signalling circuit |
| associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit |
| average impedance | 2 mOhm – Ith 50 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified |
| electrical durability | 1.65 Mcycles 32 A AC-3 at Ue <= 440 V 1.4 Mcycles 50 A AC-1 at Ue <= 440 V 1.65 Mcycles 25 A AC-3e at Ue <= 440 V |
| power dissipation per pole | 2 W AC-3 5 W AC-1 2 W AC-3e |
| Front cover | With |
| mounting support | Rail Plate |
| standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1 |
| product certifications | UL DNV CCC CSA LROS (Lloyds register of shipping) GOST RINA BV GL UKCA |
| connections – terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm²flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1…10 mm²flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm²flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm²solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²solid without cable end |
| tightening torque | Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2 Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver Philips No 2 Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2 Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2 |
| operating time | 12…22 ms closing 4…19 ms opening |
| safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| mechanical durability | 15 Mcycles |
| maximum operating rate | 3600 cyc/h 60 °C |
SCHNEIDER ELECTRIC LC1D32B7C CONTACTOR
$64
| range | TeSys TeSys Deca |
|---|---|
| product name | TeSys D TeSys Deca |
| product or component type | Contactor |
| device short name | LC1D |
| contactor application | Resistive load Motor control |
| utilisation category | AC-3 AC-4 AC-1 AC-3e |
| poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
| [Ie] rated operational current | 32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 32 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| motor power kW | 7.5 kW at 220…230 V AC 50/60 Hz (AC-3) 15 kW at 380…400 V AC 50/60 Hz (AC-3) 15 kW at 415…440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660…690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC-4) 7.5 kW at 220…230 V AC 50/60 Hz (AC-3e) 15 kW at 380…400 V AC 50/60 Hz (AC-3e) 15 kW at 415…440 V AC 50/60 Hz (AC-3e) 18.5 kW at 500 V AC 50/60 Hz (AC-3e) 18.5 kW at 660…690 V AC 50/60 Hz (AC-3e) |
| motor power HP (UL / CSA) | 2 hp at 115 V AC 50/60 Hz for 1 phase motors 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 20 hp at 460/480 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 24 V AC 50/60 Hz |
| auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| overvoltage category | III |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit 50 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 550 A at 440 V for power circuit conforming to IEC 60947 |
| rated breaking capacity | 550 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 260 A 40 °C – 10 s for power circuit 430 A 40 °C – 1 s for power circuit 60 A 40 °C – 10 min for power circuit 138 A 40 °C – 1 min for power circuit 100 A – 1 s for signalling circuit 120 A – 500 ms for signalling circuit 140 A – 100 ms for signalling circuit |
| associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit |
| average impedance | 2 mOhm – Ith 50 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified |
| electrical durability | 1.65 Mcycles 32 A AC-3 at Ue <= 440 V 1.4 Mcycles 50 A AC-1 at Ue <= 440 V 1.65 Mcycles 25 A AC-3e at Ue <= 440 V |
| power dissipation per pole | 2 W AC-3 5 W AC-1 2 W AC-3e |
| Front cover | With |
| mounting support | Rail Plate |
| standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1 |
| product certifications | UL DNV CCC CSA LROS (Lloyds register of shipping) GOST RINA BV GL UKCA |
| connections – terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm²flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1…10 mm²flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm²flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm²solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²solid without cable end |
| tightening torque | Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2 Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver Philips No 2 Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2 Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2 |
| operating time | 12…22 ms closing 4…19 ms opening |
| safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| mechanical durability | 15 Mcycles |
| maximum operating rate | 3600 cyc/h 60 °C |
CONECTOR PERMAGRIP BIMETALICO CAL 2-2/0 AWG TRODICA
CABLE TTU POLIETILENO 250MCM 600V ICONEL
SCHNEIDER ELECTRIC LRD10 Relé de sobrecarga para motor
WIKA 891.13.500 TRANSMISOR DE PRESION
3M CINTA DE URETANO 4026W DOBLE REVESTIMIENTO
TEMFLEX 1500 3M CINTA AISLANTE VINILO
9x1124 Caterpilla Sensor de presion de aceite
CINTA DE EMPAQUE TRANSPARENTE 48X35M
SIEMENS PANEL OPERADOR BASICO 6SE6400-0BP00-0AA1
PR18-8D P AUTONICS SENSOR DE PROXIMIDAD
Schneider Electric LC1D40AM7C - Contactor
ALLEN BRADLEY 100-C09D10 Contactor
A16-30-10 ABB Contactor 110V
ABB A63-30-11 - CONTACTOR
3RH1911-1FA22 SIEMENS BLOQUE DE CONTACTO 2NA+2NC
ABBF OFAF000H63 FUSIBLE 500 V
Panduit PSL-CB Dispositivo universal de bloqueo de disyuntores
Schneider Electric LC1D18 Conntactor Tesys
CONTACTOR DE POTENCIA 3RT1017-1BB41 - SIEMENS
3M CINTA USO GENERAL 1400
ABB A185-30 - Contactor
XCK-J10541 TELEMECANIQUE SENSOR
CINTA DE PREVENCION - 766 - 3M
1LA7 070-4 YA60 MOTOR ELECTRICO SIEMENS
Relé enchufable CR-P230AC2 - ABB
HAOSHI 862001 PROBADOR DE BOBINA DE ENCENDIDO AJUSTABLE
A26-30-10 ABB Contactor 













Valoraciones
No hay valoraciones aún.