| range | TeSys TeSys Deca |
|---|---|
| product name | TeSys D TeSys Deca |
| product or component type | Contactor |
| device short name | LC1D |
| contactor application | Resistive load Motor control |
| utilisation category | AC-1 AC-4 AC-3 |
| poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
| [Ie] rated operational current | 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
| motor power kW | 18.5 kW at 380…400 V AC 50/60 Hz (AC-3) 11 kW at 220…230 V AC 50/60 Hz (AC-3) 22 kW at 415…440 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 30 kW at 660…690 V AC 50/60 Hz (AC-3) 9 kW at 400 V AC 50/60 Hz (AC-4) |
| motor power HP (UL / CSA) | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 115 V AC 50/60 Hz for 1 phase motors 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors |
| control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 220 V AC 50/60 Hz |
| auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| overvoltage category | III |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit 60 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 800 A at 440 V for power circuit conforming to IEC 60947 |
Schneider Electric LC1D40AM7C – Contactor
$117
| range | TeSys TeSys Deca |
|---|---|
| product name | TeSys D TeSys Deca |
| product or component type | Contactor |
| device short name | LC1D |
| contactor application | Resistive load Motor control |
| utilisation category | AC-1 AC-4 AC-3 |
| poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
| [Ie] rated operational current | 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
| motor power kW | 18.5 kW at 380…400 V AC 50/60 Hz (AC-3) 11 kW at 220…230 V AC 50/60 Hz (AC-3) 22 kW at 415…440 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 30 kW at 660…690 V AC 50/60 Hz (AC-3) 9 kW at 400 V AC 50/60 Hz (AC-4) |
| motor power HP (UL / CSA) | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 115 V AC 50/60 Hz for 1 phase motors 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors |
| control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 220 V AC 50/60 Hz |
| auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| overvoltage category | III |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit 60 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 800 A at 440 V for power circuit conforming to IEC 60947 |
SCHNEIDER ELECTRIC LRD10 Relé de sobrecarga para motor
XS618B1PAL2 TELEMECANIQUE SENSOR DETECTOR DE PROXIMIDAD INDUCTIVO
LEVITON W5320-T0G TOMA CORRIENTE 15A-125V
ABB A63-30-11 - CONTACTOR
MITSUBISHI NF400-CS BREAKER 300AMP
ALLEN BRADLEY 100-C09D10 Contactor
SENSOR DE NIVEL DE ACEITE 6PR 008 079-02 1J0907660 B PARA AUDI A2 A3 A4
Protector Para Aires Acondicionados Y Refrigeración Gsm-Re120A - Exceline
Cable 250 Mcm Ttu 600v 100% De Cobre (por metro)
SEQUENCER MAC 3 MODULO COMANDO MULTICONTROL
SIEMENS 3RV1901-1A Bloque de contacto
SIEMENS PANEL OPERADOR BASICO 6SE6400-0BP00-0AA1
SMC AMG150C-N02D SEPARADOR DE AGUA
ABB A185-30 - Contactor
Schneider Electric LC1D32 Contactor 














Valoraciones
No hay valoraciones aún.