| range | TeSys TeSys Deca |
|---|---|
| product name | TeSys D TeSys Deca |
| product or component type | Contactor |
| device short name | LC1D |
| contactor application | Resistive load Motor control |
| utilisation category | AC-1 AC-4 AC-3 |
| poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
| [Ie] rated operational current | 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
| motor power kW | 18.5 kW at 380…400 V AC 50/60 Hz (AC-3) 11 kW at 220…230 V AC 50/60 Hz (AC-3) 22 kW at 415…440 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 30 kW at 660…690 V AC 50/60 Hz (AC-3) 9 kW at 400 V AC 50/60 Hz (AC-4) |
| motor power HP (UL / CSA) | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 115 V AC 50/60 Hz for 1 phase motors 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors |
| control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 220 V AC 50/60 Hz |
| auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| overvoltage category | III |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit 60 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 800 A at 440 V for power circuit conforming to IEC 60947 |
Schneider Electric LC1D40AM7C – Contactor
$117
| range | TeSys TeSys Deca |
|---|---|
| product name | TeSys D TeSys Deca |
| product or component type | Contactor |
| device short name | LC1D |
| contactor application | Resistive load Motor control |
| utilisation category | AC-1 AC-4 AC-3 |
| poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
| [Ie] rated operational current | 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
| motor power kW | 18.5 kW at 380…400 V AC 50/60 Hz (AC-3) 11 kW at 220…230 V AC 50/60 Hz (AC-3) 22 kW at 415…440 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 30 kW at 660…690 V AC 50/60 Hz (AC-3) 9 kW at 400 V AC 50/60 Hz (AC-4) |
| motor power HP (UL / CSA) | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 115 V AC 50/60 Hz for 1 phase motors 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors |
| control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 220 V AC 50/60 Hz |
| auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| overvoltage category | III |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit 60 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 800 A at 440 V for power circuit conforming to IEC 60947 |
A26-30-10 ABB Contactor
RAMPLUG EXPANSIBLE 1/2
STANLEY PROTO J4234B - JUEGO DE EXTRACTOR DE MANDIBULA RECTA, 10 TONELADAS
ALLEN BRADLEY 1734-AENT CONTROLADOR LOGICO
23 3M SCOTCH CINTA AISLANTE AUTOSOLDABLE
CONTACTOR DE POTENCIA 3RT1017-1BB41 - SIEMENS
ABB AF30-30-00-13 - Contactor
CSQ LC1D32 - Contactor
CONECTOR PERMAGRIP BIMETALICO CAL 2-2/0 AWG TRODICA
PR18-8D P AUTONICS SENSOR DE PROXIMIDAD
XS1M18MA230 Telemecanique Sensor de proximidad
ADAPTADOR DE ROSCA DE E40 A E27
42GRU-9200-QD Allen Bradley Sensor Fotoelectrico PhotoSwitch
BES0059 BALLUFF Sensor inductivo estándar
3M CINTA DE URETANO 4026W DOBLE REVESTIMIENTO
Bombillo Ahorrador Espiral 75 Watt Ah39 - Lumistar
Relé Termico LRD12 - Scheider Electric
MITSUBISHI NF400-CS BREAKER 300AMP
ALLEN BRADLEY 193-EECB Rele de sobrecarga
Protector Multipropósito GSM-MP - Exceline
Schneider Electric LC1D40AM7C - Contactor
UT333 UNI-T TERMOHIGROMETRO DIGITAL
BES0068 Balluff Sensor inductivo estándar
D4BS-45FS Omron - Interruptor de Limite
ALLEN BRADLEY 700-TBR24 RELE DE INTERFAZ
Temporizador 3RP1525-1BP30 - SIEMENS
Honeywell BZ-2RL-A2 Interruptor de acción básico / a presión 15A 125VAC
Relé de Sobrecarga Térmica para Motor LRD07 - Schneider Electric
Schneider Electric LC1D32 Contactor
Allen Bradley 1756-BA2 Batería de repuesto (1200 mAh, 3 V)
HF-KN43K MITSUBISHI ELECTRIC
TA25DU-25 ABB RELE DE SOBRECARGA TERMICA
Perro Para Guaya 5/16 A 1/2
CODO 45º de PVC
3RH1911-1FA22 SIEMENS BLOQUE DE CONTACTO 2NA+2NC
5WAY PENETRANTE 3M 476G
193150 GRLA-3/8-QS-8-D FESTO VÁLVULA DE ESTRANGULACIÓN Y ANTIRRETORNO
ABB A75-30 - Contactor
IDEC RH1B-U Relé de potencia
Schneider Electric LC1D18 Conntactor Tesys
Schneider Electric XB4BS8442 Botón de parada de Emergencia Roja
TENSOR PARA GUAYAS OJO Y GANCHO 1/4
ALLEN BRADLEY 2711P-T6C20D Módulo de pantalla táctil PanelView Plus 600
A12-30-10 ABB Contactor
FUSIBLE 3NA3 132-2C SIEMENS 125 AMP 500 V
9x1124 Caterpilla Sensor de presion de aceite
PARKER SENSOR DE LAMINAS PD11S3 DE 2 HILOS
Schneider Electric LC1D09M7 - Contactor
Regleta 6 Tomas Con Supresor De Pico Exceline Gmt-6-120308
NOYAFA NF-8209 TESTER CABLE
RELE TEMPORIZADOR FINDER 85.02.8.240.0000
SMC AMG150C-N02D SEPARADOR DE AGUA
CUTLER HAMMER LI630 BREAKER TRIFASICO 