TECHNICAL DATA
General
Standards
IEC/EN 60947, VDE 0660,UL, CSA
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperatureStorage
– 40 – 80 °C
Ambient temperatureOpen
-25 – +55 °C
Ambient temperatureEnclosed
– 25 – 40 °C
Mounting position
Direction of incoming supply
as required
Degree of protectionDevice
IP20
Degree of protectionTerminations
IP00
Protection against direct contact when actuated from front (EN 50274)
Finger and back-of-hand proof
Mechanical shock resistance half-sinusoidal shock 10 ms to IEC 60068-2-27
25 g
Altitude
Max. 2000 m
Terminal capacity main cableScrew terminalsSolid
1 x (1 – 6)
2 x (1 – 6) mm2
Terminal capacity main cableScrew terminalsFlexible with ferrule to DIN 46228
1 x (1 – 6)
2 x (1 – 6) mm2
Terminal capacity main cableScrew terminalsSolid or stranded
18 – 10 AWG
Terminal capacity main cableScrew terminalsStripping length
10 mm
Specified tightening torque for terminal screwsMain cable
1.7 Nm
Specified tightening torque for terminal screwsControl circuit cables
1 Nm
Main conducting paths
Rated impulse withstand voltage [Uimp]
6000 V AC
Overvoltage category/pollution degree
III/3
Rated operational voltage [Ue ]
690 V AC
Rated uninterrupted current = rated operational current [Iu = Ie ]
2.5 A
Rated frequency [f]
40 – 60 Hz
Current heat loss (3 pole at operating temperature)
5.16 W
Impedance per pole
270 mΩ
Lifespan, mechanical [Operations]
0.1 x 106
Lifespan, electrical (AC-3 at 400 V)Lifespan, electrical [Operations]
0.1 x 106
Max. operating frequency
40 Ops/h
Short-circuit ratingDCShort-circuit rating
60 kA
Short-circuit ratingDCNotes
up to 250 V
Motor switching capacityAC-3 (up to 690V)
2.5 A
Motor switching capacityDC-5 (up to 250V)
2.5 (3 contacts in series) A
Trip blocks
Temperature compensationto IEC/EN 60947, VDE 0660
– 5…40 °C
Temperature compensationOperating range
– 25…55 °C
Temperature compensation residual error for T > 40 °C
≦ 0.25 %/K
Setting range of overload releases
0.6 – 1 x Iu
short-circuit release
Basic device, fixed: 15.5 x Iu
Short-circuit release tolerance
± 20%
Phase-failure sensitivity
IEC/EN 60947-4-1, VDE 0660 Part 102
Rating data for approved types
Switching capacityMaximum motor ratingThree-phase200 V
208 V
0.5 HP
Switching capacityMaximum motor ratingThree-phase230 V
240 V
0.5 HP
Switching capacityMaximum motor ratingThree-phase460 V
480 V
1 HP
Switching capacityMaximum motor ratingThree-phase575 V
600 V
1.5 HP
Switching capacityMaximum motor ratingSingle-phase230 V
240 V
0.17 HP
Short Circuit Current Rating, type E240 V
65 kA
Short Circuit Current Rating, type E480 Y / 277 V
65 kA
Short Circuit Current Rating, type E600 Y / 347 V
50 kA
Short Circuit Current Rating, type EAccessories required
BK25/3-PKZ0-E
Short Circuit Current Rating, group protection600 V High FaultSCCR (fuse)
50 kA
Short Circuit Current Rating, group protection600 V High Faultmax. Fuse
600 A
Short Circuit Current Rating, group protection600 V High FaultSCCR (CB)
50 kA
Short Circuit Current Rating, group protection600 V High Faultmax. CB
600 A
LITTMAN REFLECTOR LED 50W MULTI VOLTAJE
SCHNEIDER ELECTRIC GV3ME80 GUARDAMOTOR
Schneider Electric XB4BS8442 Botón de parada de Emergencia Roja
Rele Termico LRD08 Telemecanique
1EW63TZZAA Jeep Cherokee Sensores De Retroceso
Relé enchufable CR-P230AC2 - ABB
RAD08314 RADWELL SENSOR
XS1M18MB230 TELEMECANIQUE DETECTOR DE PROXIMIDAD
SCHNEIDER ELECTRIC GV2-ME16C - GUARDAMOTOR
Bobina M7 Para Contactor Lc1d65m7
BOMBILLO LED 12W 6500K E27 - HAMMER
ELETTROSONDA Z11NS MAC 3
Schneider Electric GV2 ME1 6C - Guardamotor magneto térmico
LAMPARA HERMETICA HAMMER LED 2X20W 













Valoraciones
No hay valoraciones aún.